Specifications

 

Yokogawa Analog I/O modules function as signal converters; by inputting field analog signals into these modules
 

 

Yokogawa RTD Input Module AAR181-S00

 
STANDARD SPECIFICATIONS of AAR181-S00
TC/RTD Input Modules (Isolated)
AAR181A, AAT141 These modules receive signals from mV, thermocouple (TC), and RTD. They can be used in dual-redundant
 
 

Items Specifications
Model AAT141 AAR181
Number of input channels 16, isolated (*7) 12, isolated
Input signal TC: JIS C1602:1995, IEC584:1995
Type J, K, E, B(*1), R, S, T, N
mV: -100 to 150 mV, -20 to 80 mV
RTD: JIS C1604:1997, IEC751:1995
Pt100 (3-wire type)(*6)
Switching input signals TC/mV can be set individually for CH1 to CH16. CH1 to CH12 are RTD inputs.
Allowable input voltage ±5 V ±5 V
Withstanding voltage Between input and system: 1500 V AC, for 1 minute
Input resistance Power ON 2 MΩ or larger
Power OFF 2 MΩ or larger
Accuracy TC: ±30 μV
MV: ±80 μV for span (-100 to 150 mV)
±30 μV for span (-20 to 80 mV)
RTD: ±120 mΩ
Allowable total resistance of
signal source plus wiring
1000 Ω or less 40 Ω or less (wiring resistance per wire) (*2)
Effect of allowable signal source
resistance (1000 Ω)
±20 μV(*3)  
Reference junction compensation
accuracy
Within ±1 °C (*4) (*5)  
Measurement current   RTD: 1 mA
Temperature drift ±80 μV/10 °C (-100 to 150 mV input)
±30 μV/10 °C (TC/-20 to 80 mV input
±120 mΩ/10 °C (RTD input)
Data update period 1 s  
Burn-out All channels can be set together.
Setting: Not available/available (UP/DOWN)
Detection time: 60 s
 
Maximum current consumption 450 mA (5 V DC) 450 mA (5 V DC)
Weight 0.2 kg

 
Yokogawa RTD Input Module AAR181-S00
 
 
EXTERNAL DIMENSIONS of AAR181-S00 Yokogawa RTD Input Module AAR181-S00
 
 

Yokogawa RTD Input Module AAR181-S00

MODEL AND SUFFIX CODES AAR181-S00

    Description
Model AAR181 RTD Input Module (12-channel, Isolated)
  -S Standard type
Suffix
Codes
5 With no explosion protection
  E With explosion protection
  0 Basic type
  3 With ISA Standard G3 option and temperature (-20 to 70 °C) option
Option
Codes
   
  /R8S00 With Pressure Clamp Terminal Block for RTD [Model: ATR8S-00]
  /R8S10 With Pressure Clamp Terminal Block for RTD (surge absorber) [Model: ATR8S-10]
  /R8D00 With Dual Pressure Clamp Terminal Block for RTD [Model: ATR8D-00]
  /R8D10 With Dual Pressure Clamp Terminal Block for RTD (surge absorber) [Model: ATR8D-10]
  /CCC01 With Connector Cover for MIL Cable [Model: ACCC01

 
We mainly supply Yokogawa pressure transmitter, Emerson 475 field communicator, Emerson AMS Trex Device communicator, Siemens pressure transmitter, Honeywell transmitter, and the Honeywell BW gas analytics.

 

Yokogawa RTD Input Module AAR181-S00

 
Wuhan Xieyuan Automation Equipment Co., Ltd
Telephone:86-027-85583233
Mobile Phone:86-18671080257
Fax:86-027-85309780
Email:sales6@@@whxyauto.com
Skype:victordu963@@@gmail.com
Whatsapp & Viber are available
Address:6-C9,Caishen Commercial Plaza,Hankou Railway Station

 

Contact Details
WUHAN XIEYUAN AUTOMATION EQUIPMENT CO.,LTD

Contact Person: Mr. Victor

Tel: 86-027-85883233

Fax: 86-027-85309780

Send your inquiry directly to us (0 / 3000)