Yokogawa Analog I/O modules function as signal converters; by inputting field analog signals into these modules
Yokogawa TC/mV Input Module AAT145-SE0
STANDARD SPECIFICATIONS of AAT145-SE0
TC/RTD Input Modules (Isolated Channels)
AAT145, AAR145 These modules receive signals from mV, thermocouple (TC), RTD, and potentiometer (POT), and they are isolated between the field and the system as well as in between each channel. They can be used in dual-redundant configuration.
Items | Specifications | |
Model | AAT145 | AAR145 |
Number of input channels | 16, isolated channels | 16, isolated channels |
Input signal | TC: JIS C1602:1995 (*1), IEC584:1995 Type J, K, E, B (*2), R, S, T, N mV: -100 to 150 mV, -20 to 80 Mv |
RTD: JIS C1604:1997 (*3), IEC751:1995 Pt100 (3-wire type) POT: Total resistance 100 Ω to 10 kΩ Span resistance: 50 % or larger of total resistance |
Switching input signals | TC/mV can be set individually for CH1 to CH16 | RTD/POT can be selected individually for CH1 to CH16. |
Allowable input voltage | ±5 V | ±5 V |
Withstanding voltage | Between input and system: 500 V AC (for single card: 1500 V AC), For 1 minute Between input channels: 200 V AC, For 1 minute |
|
Input resistance | Power ON 1 MΩ or larger | |
Power OFF 1 MΩ or larger | ||
Accuracy | ±40 μV | RTD: ±150 mΩ POT: ±0.2 %/FS |
Allowable total resistance of signal source plus wiring |
1000 Ω or less | 150 Ω or less (wiring resistance per wire) (*4) |
Effect of allowable signal source resistance (1000 Ω) |
±20 μV | |
Reference junction compensation accuracy |
±1 °C (*5) (6) | |
Measurement current | RTD: 1 mA | |
Data update period | 1 s | |
Burn-out | All channels can be set together. Setting: not available/available (UP/DOWN) Detection time: 60 s |
|
Temperature drift | ±80 μV/10 °C | RTD: ±0.3 Ω/10 °C POT: ±0.4 %/10 °C |
Maximum current consumption |
350 mA (5 V DC) | 350 mA (5 V DC) |
Weight | 0.3 kg | |
External connection | Dedicated cable (KS1) | Dedicated cable (KS8/AKB335) |
Yokogawa TC/mV Input Module AAT145-SE0
EXTERNAL DIMENSIONS of AAT145-SE0
Description | ||
Model | AAT145 | TC/mV Input Module (16-channel, Isolated channels) |
Suffix Codes |
-S | Standard type |
5 | With no explosion protection | |
E | With explosion protection | |
0 | Basic type | |
3 | With ISA Standard G3 option and temperature (-20 to 70 °C) option |
Yokogawa TC/mV Input Module AAT145-SE0
Automation system for process and production control
CENTUM VP
CENTUM CS3000
CS300R3
Analog Model;
AAI141 AAI141-S50 AAI141-H50 AAI141-H50/K4A00 AAI141-S50/K4A00,AAI141-S50/k400 Analog Input Module (4 to 20 mA, 16-Channel, Non-Isolated)
AAV141 AAV141-S50 Analog Input Module (1 to 5 V, 16-Channel, Non-Isolated)
AAV142 AAV142-S50 Analog Input Module (-10 V to +10 V, 16-Channel, Non-Isolated)
AAI841 AAI841-S50 AAI841-H50 Analog I/O Module (4 to 20 mA Input, 4 to 20 mA Output, 8-Channel Input/8-Channel Output, Non-Isolated)
AAB841,AAB841-S50 Analog I/O Module
(1 to 5 V Input, 4 to 20 mA Output, 8-Channel Input/8-Channel Output, Non-Isolated)
AAV542,AAV542-S50 Analog Output Module (-10 V to +10 V, 16-Channel, Non-Isolated)
AAI143,AAI143-S50,AAI143-H50 AAI143-S50/k4A00 ,AAI143-S53/A4S00 AAI143-H50/K4A00,AAI143-H03,AAI143-S50/A4S00 Analog Input Module (4 to 20 mA, 16-Channel, Isolated)
AAV144,AAV144-S50 Analog Input Module (-10 V to +10 V, 16-Channel, Isolated)
AAV544,AAV544-S50 Analog Output Module (-10 V to +10 V, 16-Channel, Isolated)
AAI543,AAI543-S50,AAI543-H50 ,AAI543-H53,AAI543-S53/A4S50,AAI543-H50/K4A00,AAI543-S50/A4S00 Analog Output Module (4 to 20 mA, 16-Channel, Isolated)
AAT141,AAT141-S50 TC/mV Input Module (16-Channel, Isolated)
AAR181,AAR181-S50 RTD Input Module (12-Channel, Isolated)
AAI135,AAI135-S50,AAI135-H00 Analog Input Module (4 to 20 mA, 8-Channel, Isolated Channels)
AAI835,AAI835-S00,AAI835-H00 Analog I/O Module (4 to 20 mA, 4-Channel Input/4-Channel Output,Isolated Channels)
AAT145,AAT145-S50 TC/mV Input Module (16-Channel, Isolated Channels)
AAR145,AAR145-S50RTD/POT Input Module (16-Channel, Isolated Channels)
AAP135,AAP135-S50 AAP135-S00/K4A00 Pulse Input Module (8-Channel, Pulse Count, 0 to 10 kHz, Isolated Channels)
AAP149,AAP149-S50 Pulse Input Module for Compatible PM1 (16-Channel, Pulse Count, 0 to 6 kHz, Non-Isolated)
AAP849,AAP849-S50 Pulse Input Module/Analog Output Module (8-Channel Input/8-Channel Output, Non-Isolated)
Digital Model;
ADV151 ,ADV151-P50,ADV151-P50/D5A00,ADV151-P53/D5A00 Digital Input Module (32-Channel, 24 V DC, Isolated)
ADV141 Digital Input Module (16-Channel, 100 V to 120 V AC, Isolated)
ADV142 Digital Input Module (16-Channel, 200 V to 240 V AC, Isolated)
ADV551 ADV551-P00/D5A00,ADV551-P00/D5A00D,ADV551-P03/D5A00igital Output Module (32-Channel, 24 V DC, Isolated)
ADV157 Digital Input Module (32-Channel, 24 V DC, Pressure Clamp Terminal Support Only, Isolated)
ADV161 Digital Input Module (64-Channel, 24 V DC, Isolated)
ADV557 Digital Output Module (32-Channel, 24 V DC, Pressure Clamp Terminal Support Only, Isolated)
ADV561 Digital Output Module (64-Channel, 24 V DC, Isolated)
ADR541 Relay Output Module (16-Channel, 24 to 110 V DC/100 to 240 V AC, Isolated)
ADV859 Digital I/O Module for Compatible ST2
(16-Channel Input/16-Channel Output, Isolated Channels)
ADV159 Digital Input Module for Compatible ST3 (32-Channel Input, Isolated Channels)
ADV559 Digital Output Module for Compatible ST4 (32-Channel Output, Isolated Channels)
ADV869 Digital I/O Module for Compatible ST5
(32-Channel Input/32-Channel Output, Isolated, Common Minus Side Every 16-Channel)
ADV169 Digital Input Module for Compatible ST6
(64-Channel Input, Isolated, Common Minus Side Every 16-Channel)
ADV569 Digital Output Module for Compatible ST7
(64-Channel Output, Isolated, Common Minus Side Every 16-Channel)
ADV851 Digital I/O Module (16-Channel input, 16-Channel output, 24 V DC)
Communication Card;
ALR111,ALR111-S50,ALR111-S51 RS232C Communication Module (2-Port)
ALR121,ALR121-S50,ALR121-S51,RS-422/RS-485 Communication Module (2-Port)
ALE111,ALE111-S50,ALR111-S51 Ethernet Communication Module
ALF111,ALF111-S50,ALF111-S51 AOUNDATION fieldbus (FF-H1) Communication Module (4-Port)
ALP111,ALP111-S50,ALP111-S51 FIBUS-DPV1 Communication Module
AGS813,AGP813
S9400UK,S9129FA
DCS USB Operation Keyboard;
AIP830,AIP831
Process I/O Module Nest
AMN11,AMN22,AMN21,AMN31,AMN32,AMN33,AMN34,AMN51
NODE UNIT;
ANB10S,ANB10D,ANR10S,ANR10D,ANS20,AND20,ABC11S,ABC11D,
Field Control Unit;
AFS10S/AFG10S,AFS10D/AFG10D
AFS20S/AFG20S,AFS20D/AFG20D
AFS40S/AFS40D,AFV10D-S41201,AFV10D-S41111
AFS30S/AFS30D
ACB41
I/O Modules With Built-In Barrier
ASI133,ASI533,AST143,ASR133,ASD143,ASD533,
CPU Model
CP451-50,CP333D,CP345,CP703
ESB Bus Coupler Module
SB401,EC401,EB401,EB501,EB402
DCS Power Supply
PW601,PW602,PW604,AEP9D,PW482,ADV144-S13
DCS Relay Boards
ARM15A,ARM55D,ARM55W,ARM55T,ARM55C,SARM55C,ARS15B,ARS15M,ARS55M
DCS I/O Modules
AAM10,AAM11,AAM11B,AAM21,AAM21J,APM11,AAM50,AAM51,AMM12T,AMM22M,AMM22T,AMM22TJ,AMM32T,AMM32TJ,AMM42T,AMM52T,ADM11T,ADM12T,ADM51T,ADM52T,AMM12C,AMM22C,AMM25C,AMM32C,AMM32CJ,ADM11C,ADM51C,ADM52C,AMC80
Communication Modules
ACM11 RS-232C Communication Module
ACM12 RS-422/RS-485 Communication Module
ACM21 RS-232C General-purpose Communication Card
ACM22 RS-422/RS-485 General-purpose Communication Card
ACM71 Ethernet Communication Module (for PFCS/PFCD)
ACF11 Fieldbus Communication Module
ACP71 PROFIBUS Communication Module
Safety Control Units
SSC10S,SSC10D,SSC50C,SSC50D,SNB10D,SCP401-51,SCP451-51,SAI143-S03,SAI143-S33,
SAI143-H03,SAI143-H63,SAV144-S53,SAV144-S63,SAI533-H53,SAI533-H63,SDV144-S53,
SDV144-S63,
SDV521-S63,SDV531-S53,
SDV531-S53,SDV531-S63,SDV531-L53,SDV531-L63,SDV541-S53,SDV541-S63,
SCB100-S0,SCB110-S0,SEA4D-01,SEA4D-11,SED2D-11,SED2D-01,SED2D-11,SED4D-01,SED4D-11,
AIP602,AIP504-13,SPW481-13,SPW482-13,SPW484-13,SNT10D,SNT401-13,SNT411-13,SNT501-13,SNT511-13,SEC401-51,SSB401-53,ALR111-S51,ALR121-S51,CFS1100,CHS5100,CHS5400,CHSKM02,CHS2100,CHS2200,CHS5200,CHS5400,CFS9153,T9070CB,ST2,HHR-11F2G2,A1422EF,A1096EM,
RB301,RB401,PW302,PW701,SARM15A,SARM55C,SARM55D,SARM55CW,SARM55W
Safety instrumentated system ( SIS)
ProSafe-RS
SSC57S,SSC57D,SSC50S,SSC50D,SSC60S,SSC60D,SNB10D,ALR121,ALR111,ALE111,SNT10D,SNT401SNT501,SNT511,VI702,SAI143,SAV144,SAI533,SDV521,SDV53A,SDV144,SDV131,SDV541,SDV526,
SAT145,SAR145,SEA4D,SED2D,SED3D,SED4D,SBA4D,SBT4D,SBR4D,SBD2D,SBD4D,SRM53D,
SRM54D,STA4S,STA4D,STB4S,STB4D,
Programmable logic controller ( PLC )
FCN-RTU
Programmable logic controller ( PLC )
FA-M3R
Programmable logic controller ( PLC )
FCJ
Programmable logic controller ( PLC )
FCN
Automation systems for production machines