Sales & Support: Request A Quote
Home ProductsYokogawa Distributed Control System ( DCS )

Yokogawa Analog Output Module AAI543 AAI143 Yokogawa DCS

Yokogawa Analog Output Module AAI543 AAI143 Yokogawa DCS

Yokogawa Analog Output Module AAI543 AAI143 Yokogawa DCS

Product Details:

Place of Origin: Indonesia
Brand Name: yokogawa
Model Number: Yokogawa Analog Output Module AAI543

Payment & Shipping Terms:

Minimum Order Quantity: 1
Packaging Details: original Yokogawa package in carton
Delivery Time: in store
Payment Terms: Paypal, Aliexpress, Western Union, T/T
Supply Ability: 200 pcs / week
Minimum Order Quantity: 1
Contact Now
Detailed Product Description
Delivery Detail: Ex-stock Packaging Details: Yokogawa Original Packing, Carton Packing

 

Specifications

 

Yokogawa Analog I/O modules function as signal converters; by inputting field analog signals into these modules
 

 

Yokogawa Analog Output Module AAI543

 

STANDARD SPECIFICATIONS of AAI543

Current/Voltage Input Modules (Non-Isolated)
These modules provide 16 inputs of mainly 4 to 20 mA DC or 1 to 5 V DC standardized signals from 2-wire/4-wire transmitters.
They can be used in dual-redundant configuration.

 

 

Current Output Module (Isolated)

AAI543 provides 16 outputs of 4 – 20 mA signal. It can be used in dual-redundant configuration. (*1)

 

Items Specifications
Model AAI543
Number of output channels 16, isolated, standard switch-over
response in redundant configuration (*3)
Output signal 4 to 20 mA
Withstanding voltage Between output and system: 1500 V AC, for 1 minute (4)
Allowable load resistance 0 to 750 Ω
Circuit-open detection Less than 0.65 mA
Accuracy ±48 μA
Data update period 10 ms
Drift due to ambient temperature change ±16 μA/10 C
Maximum current consumption 230 mA (5 V DC), 540 mA (24 V DC)
Weight 0.4 kg
External communication Pressure clamp terminal, MIL connector cable, dedicated cable (KS1)
HART communication (5) Available

*1: A dual-redundant configuration is enabled by using two identical modules with the same suffix codes.
*2: When AAI543 is installed in a ER bus node unit, use it in the ambient temperature within 0 to 60 ºC range.
*3: When a switch over from control to stand-by module takes place in the dual-redundant configuration, the maximum period
of time when the field output falls below 4 mA is 100 ms for AAI543-0 (standard switch-over response) and 2 ms for
AAI543-1(fast switch-over response). In case of connecting fast response type field devices, use AAI543-1 (fast
switch-over response) in the dual-redundant configuration.
*4: When the dedicated cable is used, the withstanding voltage is 500 V AC (between the input signal and the system). When
the ML connector cable is used, the withstanding voltage depends on the electrical specifications of the cable.
*5: When this module is installed in a ER bus node unit with HART function, the EB401 firmware must be rev. 2 or later.

 

 

Yokogawa Analog Output Module AAI543

 

EXTERNAL DIMENSIONS of AAI543Yokogawa Analog Output Module AAI543 AAI143 Yokogawa DCS

 

 

Yokogawa Analog Output Module AAI543

MODEL AND SUFFIX CODES AAI543

    Description
Model AAI543 Analog Output Module (4 to 20 mA 16-channel Isolated)
  -S Standard Type
  -H With digital communication (HART protocol)
Suffix
Codes
5 Standard switch-over response in redundant configuration with no explosion protection(*1)
  6 Fast switch-over response in redundant configuration with no explosion protection(*2)
  E Standard switch-over response in redundant configuration with explosion protection(*1)
  F Fast switch-over response in redundant configuration with explosion protection(*2)
  0 Basic type
  1 With ISA Standard G3 option
  3 With ISA Standard G3 option and temperature (-20 to 70 C) option
Option
Codes
/K4A00 With KS Cable Interface Adapter [Model ATK4A-00]
  /A4S00 With Pressure Clamp Terminal Block for Analog [Model ATA4S-00]
  /A4S10 With Pressure Clamp Terminal Block for Analog (surge absorber) [Model ATA4S-10]
  /A4D00 With Dual Pressure Clamp Terminal Block for Analog [Model ATA4D-00]
  /A4D10 With Dual Pressure Clamp Terminal Block for Analog (surge absorber) [Model ATA4D-10]
  /CCC01 With Connector Cover for MIL Cable [Model ACCC01]

 

*1: If “standard switch-over response in redundant configuration” is selected, “basic type” or “with ISA Standard G3 option and
temperature (-20 to 70 °C) option” may be specified.
*2: If “fast switch-over response in redundant configuration” is selected, “basic type” or “with ISA Standard G3 option” may be
specified.

 

 

 

Yokogawa Analog Output Module AAI543

 

Contact Details
WUHAN XIEYUAN AUTOMATION EQUIPMENT CO.,LTD

Contact Person: Mr. Victor

Tel: 86-027-85883233

Fax: 86-027-85309780

Send your inquiry directly to us (0 / 3000)