Place of Origin: | UK |
Brand Name: | MTL |
Certification: | ccs2 |
Model Number: | MTL5526 Switch operated relay 2–channel IS–output From MTL INST UK, MTL Barrier |
Minimum Order Quantity: | 1 |
---|---|
Price: | 50USD per piece |
Packaging Details: | Carton |
Delivery Time: | one week |
Payment Terms: | T/T |
MTL5526 Switch operated relay 2–channel IS–output From MTL INST UK, MTL Barrier
Why do you choose us?
1. 100% original package product, 100% quality assurance.
If you find a fake product. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt Paypal, T/T, Alibaba Trade Assurance order, and other methods. If you can not trust us , you can choose to pay it via Ali-express! 100% make your money safe!
We mainly supply Yokogawa pressure transmitter, Emerson 475 field communicator, Emerson AMS Trex Device communicator, Siemens pressure transmitter, Honeywell transmitter, and the Honeywell BW gas analytics.
Wuhan Xieyuan Automation Equipment Co., Ltd
Telephone:86-027-85583233
Mobile Phone:86-18671080257
Fax:86-027-85309780
Contact : victor@whxyauto.com
Skype:victordu963@gmail.com
Whatsapp & Viber are available
Address:6-C9,Caishen Commercial Plaza,Hankou Railway Station
MTL5526 Switch operated relay 2–channel IS–output From MTL INST UK, MTL Barrier
MTL5526 Switch operated relay 2–channel IS–output
MTL5526 enables two separate IS circuits in a hazardous area to be contact controlled by one or two, on/off, control signals in a safe area. Applications include the calibration of strain–gauge bridges; changing the polarity (and thereby the tone) of an IS sounder; the testing of IS fire alarms; and the transfer of safe-area signals into an annunciator with IS input terminals not segregated from each other. The output–relay contacts are certified as non–energy–storing apparatus, and can be connected to any IS circuit without further certification, provided that separate IS circuits are such that they would remain safe if connected together.
SPECIFICATION FOR MTL5526
See also common specification
Number of channels
Two, fully floating
Location of control circuit
Safe area
Input/output characteristics
Contact/Logic mode
(Inputs suitable for switch contacts, an open–collector transistor or logic drive)
Relay energised if < 450Ω or < 1V applied
Relay de–energised if > 5kΩ or > 2V applied (35V max.)
Loop powered mode
Relay energised if >20V
Relay de-energised if <17V
Power supply failure protection
Relays de–energised if supply fails
Response time
25ms nominal
Contacts (suitable for connection to IS circuits)
1–pole changeover per channel
Contact rating
250V dc, limited to 30V dc for IS applications, 2A
(reactive loads must be suppressed)
Contact life expectancy
2 x 107operations at maximum IS load
Relay drive (see switch setting table)
Choice of "loop-powered" or "contact/logic" control, for both
channels, by switch selection. A further switch option ("1in2out")
enables either input, in contact/logic mode, to activate both outputs.