Sales & Support: Request A Quote
Home ProductsABB

IEC outdoor gas insulated (SF6) circuit breaker OHB

IEC outdoor gas insulated (SF6) circuit breaker OHB

    • IEC outdoor gas insulated (SF6) circuit breaker OHB
    • IEC outdoor gas insulated (SF6) circuit breaker OHB
    • IEC outdoor gas insulated (SF6) circuit breaker OHB
  • IEC outdoor gas insulated (SF6) circuit breaker OHB

    Product Details:

    Place of Origin: ABB
    Brand Name: abb
    Model Number: (SF6) circuit breaker OHB
    Contact Now
    Detailed Product Description

    IEC outdoor gas insulated (SF6) circuit breaker OHB

     

    Medium Voltage circuit breaker with mechanical operating mechanism designed for distribution systems up to 40.5 kV, 2500 A, 31.5 kA.

    These circuit breakers are of live tank design. They are used in power distribution for control and protection of lines and for control and protection of transformers, rectifier units, capacitor banks, etc. Thanks to the autopuffer breaking technique, they do not generate operating overvoltages. This means they are also highly suitable for retrofitting, where the plant insulating materials may be sensitive to dielectric stresses.

    Why ABB?

    § Maintenance-free poles

    § Upper and lower terminals with NEMA4 drilling

    § Gas pressure control device for each pole

    § Poles made with porcelain insulators, assembled by means of flanges with terminals

    § Inspection window in the pole supporting casing near the operating mechanism signals.

     

     

     

     

    *************************************************************************************************

     

    IEC indoor railways vacuum circuit breaker GSR+

     

     

     

    IEC indoor railways vacuum circuit breaker GSR+

    Medium Voltage single-phase circuit breaker with magnetic actuator, designed for railway power supply up to 27.5 kV, 2500 A, 31.5 kA

    The GSR+ II range is the first commercially available single-phase vacuum circuit breaker for railway power supply applications to feature a vacuum interrupter, magnetic actuator and electronic controller. This solution is robust, reliable and essentially maintenance-free.

     

    Ratings  
    Rated frequency (Hz) 50
    Rated voltage (kV) 31.5
    Rated power frequency withstand voltage (kV) 95
    Lightning impulse withstand voltage (kV) 185
    Rated current (A) 1250 / 1600 / 2000 / 2500
    Rated short-circuit breaking current (kA) 25 / 31.5
    Rated short-circuit making current (kA) 63 / 80

     

    Why ABB?

    § Available in single- (1x25 kV, 1x15 kV) and two-phase (2x25 kV) configurations

    § Available for 16.7 (25) Hz and 50 (60) Hz networks

    § Easy to interface, adapt and integrate into new or existing installations

    § Easy to install and commission

    § Fewer moving parts

     

     

     

     

    *****************************************************************************************************

     

     

    IEC outdoor AC railways vacuum circuit breaker FSK II+

    IEC outdoor gas insulated (SF6) circuit breaker OHB

    MV single or two-phase circuit breaker with magnetic actuator designed for railway power supply up to 27.5 kV, 2500 A, 25 kA / 31.5 kA.

    FSK II+ is an evolutionary process that builds on the success established by the FSK II over the past 10 years thanks to key advantages such as the use of environmentally friendly N2 (nitrogen), its reduced footprint and the VE1 single vacuum interrupter, yet it also incorporates some important innovations, such as the externally bolted HV terminals and the polymeric insulators. The FSK II + is electromechanically compatible, as well as offering a high level of flexibility and reliability to meet individual requirements.

    Why ABB?

    § Alternative technologies with low environmental impact

    § Polymeric insulator

    § Same design for single-phase and two-phase configurations

    § On Site configurable High Voltage Terminations orientation

    § Compact footprint

     

    Are you looking for support or purchase information?

    Contact us https://search-ext.abb.com/library/Download.aspx?DocumentID=1VSR632510&LanguageCode=en&DocumentPartId=&Action=Launch

     

     

     

     

    Downloads for Outdoor AC Railway Circuit Breaker FSK II+

    ****************************************************************************************

     

     

    DC rolling stock circuit breaker DCBreak

    Medium voltage high-speed bi-directional DC circuit breaker for rolling stock application power supply up to 900 V, 1500 A.

    The DCBreak circuit breaker family for rolling stock combines a small footprint, reduced weight, high flexibility and reliable operation with minimal maintenance. It is ABB’s first in a line of new products intended for the direct current railway transportation market. It is designed to high safety standards as well as relevant environmental directives and industry standards.

    Engineered with flexibility in mind, it is as easy to implement in new builds as well as retrofit into existing ones, and its simplified design makes for reduced maintenance time and costs.

    DCBreak product range

    § Rated operational voltage 900 V, rated current 1500 A, breaking capacity 30 kA

    Main benefits

    § Space savings

    § Technology with low environmental impact

    § Reduced handling time and maintenance cost

    § Fast and safe installation in new as well as existing vehicles

    Main features

    § Compact design with 40 % less footprint and weight just 28 kg

    § Cadmium-free contacts for reduced environmental impact (RoHS compliant)

    § Easy to service due to over 200,000 maintenance free operations

    § Simple plug-and-play replacement of majority of circuit breakers available on the market currently

    § Possible to install in the undercarriage as well as the overhead

    § Functional blocks based design simplifies maintenance operations and reduces costs

    § Conformity to railway standards

     

    ********************************************************************************************

     

    IEC/ANSI indoor vacuum circuit breaker Vmax

    Medium Voltage circuit breaker with mechanical actuator (spring mechanism) for primary distribution, up to 17.5 kV, 2000 A, 31.5 kA.

    Vmax breakers are used in electrical distribution for control and protection of cables, overhead lines, transformer and distribution substations, motors, and transformers.

    The Vmax breaker family is available for IEC and ANSI applications:

    § Vmax/W breaker is sold as an ANSI or IEC OEM offering as a stand-alone breaker or with a PowerCube

    § Vmax/L breaker is designed for use with the IEC UniGear 550 product, or can be sold as an IEC-rated OEM offering as a standalone breaker or with a PowerCube

    § Vmax/A breaker is designed:

    § for use with the ANSI metal-clad switchgear ReliaGear ND product

    § as an ANSI OEM offering with a breaker compartment, L-frame, or kit

     

    Why ABB?

    § Stored energy operating mechanism with mechanical anti-pumping device supplied as standard

    § Fixed and withdrawable versions with front operating mechanism

    § Circuit​ breaker racking-in and racking-out with the door closed

    § Vmax breaker is the easiest spring-charged mechanical breaker to maintain in the industry

     

     

     

    *********************************************************************************************

     

     

    IEC indoor vacuum circuit breaker VD4

    Medium Voltage circuit breakers with mechanical actuator (spring mechanism) for primary distribution up to 46 kV, 4000 A, 63 kA. IEC outdoor gas insulated (SF6) circuit breaker OHB

    VD4 circuit breakers are used in electrical distribution for control and protection of cables, overhead lines, transformer and distribution substations, motors, transformers, generators and capacitor banks.
    Up to 4000 A in switchgear with forced ventilation

    Why ABB?

    § Sealed-for-life poles

    § Operation under different climatic conditions

    § Stored energy operating mechanism with anti-pumping device supplied as standard

    § Fixed and withdrawable versions with front operating mechanism

    § Circuit-breaker racking-in and racking-out with the door closed

     

     

    *******************************************************************************************

    IEC indoor vacuum circuit breaker VM1

    Medium Voltage circuit breakers with magnetic actuator for primary distribution up to 24 kV, 3150 A (4000*), 50 kA.

    VM1 circuit breakers are used in primary power distribution for control and protection of cables, overhead lines, substations, motors, transformers, generators, capacitor banks, etc. in plants such as: chemical industries, steelworks, automobile industries, airports, large buildings and shopping malls. The magnetic drive activate the moving contacts of the interrupters and integrates all the functions of a traditional drive.
    * Up to 4000 A in switchgear with forced ventilation

    Why ABB? IEC outdoor gas insulated (SF6) circuit breaker OHB

    § Sealed-for-life poles

    § Operation under different climatic conditions

    § Anti-pumping device supplied as standard

    § Fixed and withdrawable versions with front operating mechanism

    § Circuit-breaker racking-in and racking-out with the door closed

    § Up to 4000 A in switchgear with forced ventilation

     

     

     

     

     

     

     

     

    *******************************************************************************

     

     

    IEC indoor vacuum circuit breaker VInd IEC outdoor gas insulated (SF6) circuit breaker OHB

    Medium Voltage circuit breaker with mechanical actuator (spring mechanism), up to 12 kV, 1250 A, 26.3 kA

    VInd circuit breakers are used in primary electrical distribution switchgear ZN1 for control and protection of cables, motors, transformers, etc.

    Why ABB?

    § Sealed-for-life poles

    § Stored energy operating mechanism with anti-pumping device supplied as standard

    § Fixed and withdrawable versions with front operating mechanism

    § Circuit-breaker racking-in and racking-out with the door closed

    § Incorporated closing spring charging lever

     

    Contact Details
    WUHAN XIEYUAN AUTOMATION EQUIPMENT CO.,LTD

    Contact Person: Mr. Victor

    Tel: 86-027-85883233

    Fax: 86-027-85309780

    Send your inquiry directly to us (0 / 3000)