Place of Origin: | China |
Brand Name: | FLUKE |
Model Number: | 744 |
Minimum Order Quantity: | 1 |
---|---|
Price: | negotiable |
Packaging Details: | Standard FLUKE packing with larger carton to protect the materials |
Delivery Time: | 6-8 weeks |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 500pcs per week |
Warranty Time: | 12 Months | Lead Time: | 8-10 Weeks |
---|---|---|---|
Packing: | Standard FLUKE Packing With Larger Carton To Protect The Materials | Quantity: | 100% Original And Genuine |
Place Of Origin: | China |
Fluke 744 Documenting Process Calibrator with HART capability
overview
As more and more process plants begin to take advantage of smart transmitters, the need for a new generation of calibrators has emerged-calibrators that can communicate via industry standard digital protocols. The 744 combines HART communication capability to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation.
The 744 does the work of several tools - sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device.
For documentation, the 744 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations.
Fluke 744 Documenting Process Calibrator with HART capability
The 744 is a power multifunction documenting calibrator that lets you download procedures, lists, and instructions created with software-or upload data for printing, archiving, and analysis. The 744 also features a powerful built in HART® interface capable of performing nearly all the day-to-day tasks you now perform with a separate communicator.
HART Capabilities
The 744 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers the communication capabilities of the 275 HART communicator.
Versatile HART Protocol support
The 744 supports the commands contained in HART protocol Version 5.7. With 2 MB of memory, the 744 supports a substantial set of HART instructions:
HART Operating Modes Supported
Fluke 744 Final Release Firmware Upgrade »
Pressure Modules
Covers virtually any pressure application including gauge, differential, dual (compound), absolute, and vacuum.
A family of 29 optional pressure modules provides pressure calibration and measurement capabilities. Twenty-eight modules are available, with basic accuracy specs to 0.05%. Ranges start at 0 – 1 inH20 (0 – .25kPa) and go to 0 – 10,000 psi (0 – 70,000 kPa). Additional information about pressure modules is available on the Pressure Modules Home Page.
Automated Procedures
Allow you to quickly set up powerful, automated calibration procedures for linear transmitters, DP flow transmitters, and one- and two-point limit switches. Simply select the appropriate measure and/or source functions and fill out the procedure template. The 740 Series does the rest. It quickly performs the test, calculates the errors, and displays the final results, highlighting out of tolerance points.
Custom Units
Enable you to map one unit to another, such as mV to °C or °F. Allows you to use the Fluke 740 Series with millivolt output accessories such as the Fluke 80T-IR Temperature Probe, and to document tests using non-supported units such as parts per million or revolutions per minute.
User-entered Values
Enables technicians to record calibration results that were sourced and/or measured by other devices such as panel meters or readout-only devices.
Limit Switch Calibration
Procedures perform fast, automated calibration of one and two-point limit switches for voltage, current, temperature, and pressure.
Differential Pressure Flow Instrument Calibration
Routines use a square root function to directly calibrate DP flow instruments.
Additional Features
Multifunctional
Calibrate temperature, pressure, voltage, current, resistance, and frequency. Since it both measures and sources, you can troubleshoot and calibrate all with one rugged tool.
Powerful, yet easy to use
The easy-to-follow menu-driven display guides you through any task. Get up to speed in minutes, not days. Programmable calibration routines enable you to create and run automated as-found/as-left procedures to ensure fast, consistent, calibrations.
Records and documents results
To support your ISO-9000 or regulatory standards the Fluke 744 captures your calibration results, eliminating the need to juggle a pen and pad in the field. The RS-232 interface lets you transfer the results to a PC, thus saving the time of having to manually transcribe them when you return to the shop.
Truly hand-held
Small enough to fit easily into a tool bag and to use in tight spaces. Runs an entire shift on a rechargeable NiMH battery pack.
Rugged and reliable
Count on Fluke's rugged design to deliver top accuracy and reliability in harsh environments. Overmolded urethane case stands up to rough handling in industrial environments.
Bright white display
Lets you read your results in any kind of light.
Soft keys
Provide one-touch access to enhanced functions such as task lists, automated procedures, scaling, min/max, stepping and ramping, and review memory.
Three operating modes
Measure, Source, or simultaneous Measure/Source, - enable technicians to troubleshoot, calibrate, or maintain instrumentation with just one tool.
Multi-lingual interface
Displays instructions in English, French, German, Spanish, and Italian.
Built-in algebraic calculator
With four functions-plus square root-stores, recalls, and performs calculations required for setting up instruments or evaluating data in the field. Use it to set the source function to a calculated value. There's no need to carry a pencil and paper or a separate calculator.
Programmable measurement delay
Inside automated procedures permits calibrating instruments that respond slowly.
Fluke 744 Documenting Process Calibrator with HART capability
Measurement Accuracy | ||
Voltage DC | 110.000 mV | 0.025% + 0.015%1 |
1.10000 V | 0.025% + 0.005%1 | |
11.0000 V | 0.025% + 0.005%1 | |
110.000 V | 0.05% + 0.005%1 | |
300.00 V | 0.05% + 0.005%1 | |
Voltage AC | 20 to 40 Hz | 2% + 10 |
40 to 500 Hz | 0.5% + 5 | |
500 to 1 kHz | 2% + 10 | |
1 kHz to 5 kHz | 10% + 20 | |
Ranges | 1.1000, 11.000, 110.00, 300 V | |
Current DC | 30.000 mA | 0.01% + 0.015%1 |
110.00 mA | 0.01% + 0.015%1 | |
Resistance | 11.000 Ω | 0.05% + 50 mΩ |
110.00 Ω | 0.05% + 50 mΩ | |
1.1000 kΩ | 0.05% + 500 mΩ | |
11.000 kΩ | 0.1% + 10 Ω | |
Frequency | 1.00 to 109.99 Hz | 0.05 Hz |
110.0 to 1099.9 Hz | 0.5 Hz | |
1.100 to 10.999 kHz | 5 Hz | |
11.00 to 50.00 kHz | 50 Hz | |
Pressure | Accuracy | from 0.025% of range using any of 29 pressure modules. |
Modules available for differential, gauge, vacuum, absolute, dual and high pressure. (for detailed specifications refer to pressure modules in options and accessories) |
||
1. (% of reading + % of full scale) | ||
Source Accuracy | ||
Voltage DC | 110.000 mV | 0.01% + 0.005%1 |
1.10000 V | 0.01% + 0.005%1 | |
15.0000 V | 0.01% + 0.005%1 | |
Current DC | 22.000 mA (Source) | 0.01% + 0.015%1 |
22.000 mA (Simulate) | 0.02% + 0.03%1 | |
Resistance | 11.000 Ω | 0.01% + 20 mΩ |
110.00 Ω | 0.01% + 40 mΩ | |
1.1000 kΩ | 0.02% + 500 mΩ | |
11.000 kΩ | 0.03% + 5 Ω | |
Frequency | 0.00 to 10.99 Hz | 0.01 Hz |
11.00 to 109.99 Hz | 0.1 Hz | |
110.0 to 1099.9 Hz | 0.1 Hz | |
1100 to 21999 Hz | 2 Hz | |
22.000 to 50.000 kHz | 5 Hz | |
1. (% of reading + % of full scale) | ||
RTDs and Thermocouples | ||
Measure accuracy | 10 Ω Cu (427) | 2°C |
100 Ω Pt (3916) | 0.3°C | |
100 Ω Pt (3926) | 0.3°C | |
100 Ω Pt (385) | 0.3°C | |
200 Ω Pt (385) | 0.3°C | |
500 Ω Pt (385) | 0.3°C | |
1000 Ω Pt (385) | 0.3°C | |
120 Ω Ni (672) | 0.3°C | |
For 2-and 3-wire measurement, add 0.4°C | ||
E | 0.3°C | |
N | 0.5°C | |
J | 0.3°C | |
L | 0.3°C | |
K | 0.3°C | |
T | 0.3°C | |
U | 0.3°C | |
B | 0.9°C | |
R | 1.0°C | |
S | 0.9°C | |
C | 0.6°C | |
BP | 1.2°C | |
XK | 0.4°C | |
Accuracy with external cold junction, for internal junction add 0.2°C | ||
Source accuracy | 10 Ω Cu (427) | 1°C |
100 Ω Pt (3916) | 0.1°C | |
100 Ω Pt (3926) | 0.1°C | |
100 Ω Pt (385) | 0.1°C | |
200 Ω Pt (385) | 0.1°C | |
500 Ω Pt (385) | 0.1°C | |
1000 Ω Pt (385) | 0.1°C | |
120 Ω Ni (672) | 0.1°C | |
For 2-and 3-wire simulation, add 0.4°C | ||
E | 0.2°C | |
N | 0.3°C | |
J | 0.2°C | |
L | 0.2°C | |
K | 0.3°C | |
T | 0.3°C | |
U | 0.3°C | |
B | 0.8°C | |
R | 0.9°C | |
S | 0.9°C | |
C | 0.6°C | |
BP | 0.5°C | |
XK | 0.4°C | |
Accuracy with external cold junction, for internal junction add 0.2°C | ||
Technical Data | ||
Data log functions | Measure functions | Voltage, current, resistance, frequency, temperature, pressure |
Reading rate | 1, 2, 5, 10, 20, 30, or 60 readings/minute | |
Maximum record length | 8000 readings (7980 for 30 or 60 readings/minute) | |
Ramp functions | Source functions | Voltage, current, resistance, frequency, temperature |
Rate | 4 steps/second | |
Trip detect | Continuity or voltage (continuity detection not available when sourcing current) | |
Loop power function | Voltage | Selectable, 24 V or 28 V |
Accuracy | 5% | |
Maximum current | 22 mA, short circuit protected | |
Maximum input voltage | 30 V DC | |
Step functions | Source functions | Voltage, current, resistance, frequency, temperature |
Manual Step | Selectable step, change with arrow buttons | |
Autostep | Fully programmable for function, start delay, stepvalue, time per step, repeat | |
Environmental Specifications | ||
Operating temperature | -10°C to +50°C | |
-20°C to +50°C2 | ||
Storage temperature | -20°C to +60°C | |
Dust/water resistance | Meets IP52, IEC 529 | |
Operating Altitude | 2800 m | |
2. Except frequency and AC | ||
Safety Specifications | ||
Agency approvals | CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-11993 | |
Mechanical and General Specifications | ||
Size | 130 x 236 x 61 mm (5.1 x 9.3 x 2.4 in) | |
Weight | 1.4 kg (3 lbs, 1 oz) | |
Batteries | NiMH 7.2V, 3.5 Ah | |
Battery life | >10 hours typical | |
Battery replacement | Via snap-shut door without opening calibrator; no tools required | |
Side port connections | Pressure module connector | |
RS-232 connector for PC interface cable and for HART communication cable | ||
Connection for optional battery eliminator | ||
Data storage capacity | 1 week of calibration results | |
90 day specifications | The standard specification interval for the 744 is 1 and 2 years. | |
Typical 90 day measurement and source accuracy can be estimated by dividing the one year "% of reading" or "% of output" specifications by 2. |
||
Floor specifications, expressed as "% of full scale" or "counts" or "ohms" remain constant. |
contact
Why do you choose us?
1. 100% original package product, 100% quality assurance.
If you find a fake product. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt Paypal, T/T, Alibaba Trade Assurance order, and other methods. If you can not trust us , you can choose to pay it the other way! 100% make your money safe!
We mainly supply Yokogawa, Emerson, Rosemount, Honeywell, Siemens, ABB, FLUKE,Endress+Hauser,SchneiderElectric,Moeller,FUJI,Omron,+,Hima, Yaskawa,Norgren, CHINT,Hach,Weidmuller,Phoenix,MTL,SMC,Testo,Rockwell ect.
Wuhan Xieyuan Automation Equipment Co., Ltd
Telephone:86-027-85583233
Mobile Phone:86-18671080257
Fax:86-027-85309780
Contact : victor@whxyauto.com
Skype:victordu963@gmail.com
Whatsapp & Viber are available
Address:7-A16,Caishen Commercial Plaza,Hankou Railway Station