Sales & Support: Request A Quote
Home ProductsHoneywell

Honeywell Gas Detectors Hydrogen sulfide (H2S) 0-15 ppm (10 to 50 ppm, 1 ppm) Sensor XNXXSH1SS

Honeywell Gas Detectors Hydrogen sulfide (H2S) 0-15 ppm (10 to 50 ppm, 1 ppm) Sensor XNXXSH1SS

    • Honeywell Gas Detectors Hydrogen sulfide (H2S) 0-15 ppm (10 to 50 ppm, 1 ppm) Sensor XNXXSH1SS
    • Honeywell Gas Detectors Hydrogen sulfide (H2S) 0-15 ppm (10 to 50 ppm, 1 ppm) Sensor XNXXSH1SS
  • Honeywell Gas Detectors Hydrogen sulfide (H2S) 0-15 ppm (10 to 50 ppm, 1 ppm) Sensor XNXXSH1SS

    Product Details:

    Place of Origin: United States
    Brand Name: Honeywell
    Model Number: XNXXSH1SS

    Payment & Shipping Terms:

    Minimum Order Quantity: 1
    Price: negotiable
    Packaging Details: Original Honeywell sensor packing or wooden packing according the requests
    Delivery Time: At Stock
    Payment Terms: TT/Paypal / Aliexpress / Western Union
    Supply Ability: 200 pcs / week
    Contact Now
    Detailed Product Description
    Type: Gas Detector Model Number: XNXXSH1SS
    Product Name: XNX Sensors Sensor: Hydrogen Sulfide (H2S)

    Honeywell Gas Detectors Hydrogen sulfide (H2S) 0-15 ppm (10 to 50 ppm, 1 ppm) Sensor XNXXSH1SS

     

    XNX Universal Transmitter

    C2H4, C3H8, C4H10, C5H12, C6H12O2, C6H14, C7H8, CH4, Cl2, ClO2, CO, CO2, H2, H2S, HCl, HF, LEL, NH3, NO, NO2, O2, PH3, SO2

     

    XNX™ Universal Transmitter w/ (EC) Electrochemical Sensors.
    The XNX's advantage comes from a simple-to-use, low-maintenance universal platform that works with other safety equipment on a digital bus system, including Analytics’ own Searchline Excel, Optima or other gas detectors, industry standard PLCs and third-party gas monitoring controllers. XNX™ supports Electrochemical, Infrared and Catalytic Bead gas monitors and uses standard 4-20mA wiring and HART; options include Modbus, Fieldbus (pending) up to three relays and a local Hart Adapter for configuration and diagnostics using existing HART handheld devices. With 200+ unique configurations, XNX™ satisfies Class 1/Class 2 intrinsically safe, explosion-proof requirements in upstream/downstream oil, chemical, wastewater and other industries. The enclosure is available in stainless steel or aluminum, with a marine-grade coating. Five threaded ports, available in metric or NPT versions, and ruggedized mounting options provide ultimate installation flexibility. Instrumentation built on various sensing technologies can be attached locally to the transmitter or remotely with the appropriate accessories. The XNX™ user interface provides Alarm, Fault and configuration support via a large dot matrix display and LED indicators. Icons supported by seven language selections are used to ensure ease of operation around the world. The XNX™ Universal Transmitter, now with HART EDDL, marks a new turn in gas detection from Analytics. It supports the widest range of sensors on a common platform and offers a modular choice of inputs and outputs. XNX is designed for flexible integration, simple installation, user-friendly operation and straight-forward maintenance. It is ideal for use with a range of gas monitoring controllers or industry standard PLCs. The introduction of our HART Enhanced Device Descriptor Language (EDDL) software provides users with an at-a-glance indication of the health of their gas detectors in the field.

    High performance
    • Flammable gas detection 0 to 100% LFL/LEL
    • Point IR with heated optics provides immunity to poisoning and no hidden faults
    • Open-path IR flammable gas detection in LEL-m measurement
    • Electrochemical cell offers toxic gas detection in ppm
    • IR cell provides CO2 and combustible gas monitoring
    • Robust and reliable operation in explosive areas and harsh environments

     

    Honeywell H2S Sensor XNXXSH1FM Hydrogen sulfide (H2S) 10-50 ppm (FM approved) XNX Sensors H2S Sensor

    Cost Effective
    • Minimal training required
    • One-man operation
    • Plug-in sensor replacement
    • All necessary accessories included

     

    Honeywell H2S Sensor XNXXSH1FM Hydrogen sulfide (H2S) 10-50 ppm (FM approved) XNX Sensors H2S Sensor

    Flexible Operation
    • 3 versions - supports (Catalytic Bead and IR Cell), Electrochemical Cell and IR (point and open-path) gas detection
    • Multi-Purpose Detector (MPD) with field serviceable mV, Catalytic bead and IR Cell capability
    • 4-20 mA with HART® as standard
    • HART Enhanced Device Description Language (EDDL) software*
    • Multiple communications options include up to 3 relays, Modbus® and FOUNDATION® H1 Fieldbus
    • Optional local IS port for handheld HART configurator

     

    Honeywell H2S Sensor XNXXSH1FM Hydrogen sulfide (H2S) 10-50 ppm (FM approved) XNX Sensors H2S Sensor

    Easy to Install
    • 3 or 4 wire operation, source, sink or isolated
    • Simple plug-in sensors and replaceable cells
    • NEMA 4X IP66 rated for rugged indoor/outdoor use
    • Five conduit entries for ease of installation

     

    Honeywell H2S Sensor XNXXSH1FM Hydrogen sulfide (H2S) 10-50 ppm (FM approved) XNX Sensors H2S Sensor

    Easy to Use
    Large, backlit, easy-to-viewLCD display offers multisensory indicators (visual icons, colored buttons, text, etc.) to display gas and sensor readings
    User interface supported by 8 selectable languages (English, Spanish, German, Italian, Portuguese, French, Russian, Chinese)
    Self-test and fault indication features
    Non-intrusive, one-man operation
    Quick calibration with auto-inhibit

     

    Honeywell H2S Sensor XNXXSH1FM Hydrogen sulfide (H2S) 10-50 ppm (FM approved) XNX Sensors H2S Sensor

    Certifications
    • UL, CSA, FM, DEMKO, DEKRA, InMetro, TUV, ABS, HART, FIELDBus Foundation, GOST and KTL approved for Hazardous Locations, Gas Performance and SIL 2 ratings among others
    • Class I, Div 1, Groups B, C & D; Class II, Div 1, Groups F and G; Hazardous Locations
    • Class I Zone 1 Group IIC, Class II, Zone 20 & 21
    • Intrinsically safe barriers for HART and EC connections
    • For additional information on certifications and approvals contact Analytics

     

     

    XNX™ Universal Transmitter (continued)
    Honeywell H2S Sensor XNXXSH1FM Hydrogen sulfide (H2S) 10-50 ppm (FM approved) XNX Sensors H2S Sensor
    Toxic and Oxygen Smart Sensors
    A wide range of toxic and oxygen sensors, featuring patented Surecell™ and Reflex technology, are available for use with the XNX™
    Universal Transmitter. Featuring a field replaceable sensor, these sensors are shipped pre-calibrated to the range listed below.
     
    XNX™ Sensors & Part Number
    Oxygen (O2) 23% v/v fixed (FM approved) XNXXSO1FM
    Oxygen (O2) 0-25% v/v XNXXSO1SS
    Carbon monoxide (CO) 0-300 ppm (100 to 1,000 ppm, 100 ppm) XNXXSC1SS
    Carbon monoxide (CO) 100-1000 ppm (FM approved) XNXXSC1FM
    Hydrogen sulfide (H2S) 0-15 ppm XNXXSH3SS
    Hydrogen sulfide (H2S) 10-50 ppm (FM approved) XNXXSH1FM
    Hydrogen sulfide (H2S) 0-15 ppm (10 to 50 ppm, 1 ppm) XNXXSH1SS
    Hydrogen sulfide (H2S) 0-100 ppm (50 to 500 ppm, 10 ppm) XNXXSH2SS
    Chlorine (Cl2) 0-5.0 ppm (5.0 to 20.0 ppm, 5.0 ppm) XNXXSL1SS
    Chlorine (Cl2) 0-5.00 ppm fixed range XNXXSL2SS
    Sulfur dioxide (SO2) 0-15.0 ppm (5.0 to 20.0 ppm, 5.0 ppm) XNXXSS1SS
    Sulfur dioxide (SO2) 0-50.0 ppm (20.0 to 50 ppm, 10 ppm) XNXXSS2SS
    Chlorine dioxide (ClO2) 0-1.00 ppm XNXXSX1SS
    Nitric oxide (NO) 0-100 ppm XNXXSM1SS
    Nitrogen dioxide (NO2) 0-10.0 ppm (5.0 to 50.0 ppm, 5.0 ppm) XNXXSN1SS
    Hydrogen (H2) 0-1000 ppm XNXXSG1SS
    Hydrogen (H2) 0-10,000 ppm XNXXSG2SS
    Hydrogen fluoride (HF) 0-12.0 ppm XNXXSF1SS
    Ammonia (NH3) 0-200 ppm (50 to 200 ppm, 50 ppm) XNXXSA1SS
    Ammonia (NH3) 0-1000 ppm (200 to 1000 ppm, 50 ppm) XNXXSA2SS
    Phosphine (PH3) 0-1.2 ppm XNXXSP1SS
    Hydrogen chloride (HCl) 0-10 ppm (10 to 20 ppm, 1 ppm) XNXXSR1SS
     
    Honeywell Gas Detectors Hydrogen sulfide (H2S) 0-15 ppm (10 to 50 ppm, 1 ppm) Sensor XNXXSH1SS

     

    Contact

    Why do you choose us?
    1. 100% original package product, 100% quality assurance.
    If you find a fake product. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
    2. Varied payment methods.
    We adopt Paypal, T/T, Alibaba Trade Assurance order, and other methods. If you can not trust us , you can choose to pay it the other way! 100% make your money safe!
     
    We mainly supply Yokogawa, Emerson, Rosemount, Honeywell, Siemens, ABB, FLUKE,Endress+Hauser,SchneiderElectric,Moeller,FUJI,Omron,+,Hima, Yaskawa,Norgren, CHINT,Hach,Weidmuller,Phoenix,MTL,SMC,Testo,Rockwell ect.

    Wuhan Xieyuan Automation Equipment Co., Ltd
    Telephone:86-027-85583233
    Mobile Phone:86-18671080257
    Fax:86-027-85309780
    Skype:victordu963 @ gmail.com
    Whatsapp & Viber are available
    Address:6-C9,Caishen Commercial Plaza,Hankou Railway Station

    Honeywell Gas Detectors Hydrogen sulfide (H2S) 0-15 ppm (10 to 50 ppm, 1 ppm) Sensor XNXXSH1SS

    Contact Details
    WUHAN XIEYUAN AUTOMATION EQUIPMENT CO.,LTD

    Contact Person: Mr. Victor

    Tel: 86-027-85883233

    Fax: 86-027-85309780

    Send your inquiry directly to us (0 / 3000)