Sales & Support: Request A Quote
Home ProductsYOKOGAWA Pressure Transmitters

Origional Yokogawa EJX-A series differential pressure transmitter EJX930A

Origional Yokogawa EJX-A series differential pressure transmitter EJX930A

    • Origional Yokogawa EJX-A series differential pressure transmitter EJX930A
    • Origional Yokogawa EJX-A series differential pressure transmitter EJX930A
  • Origional Yokogawa EJX-A series differential pressure transmitter EJX930A

    Product Details:

    Place of Origin: Japan
    Brand Name: YOKOGAWA
    Certification: ss
    Model Number: EJX930A

    Payment & Shipping Terms:

    Minimum Order Quantity: 1
    Price: 700-1500USD per piece
    Packaging Details: Standard Yokogawa packing with larger carton to protect the materials
    Delivery Time: 8-10 weeks
    Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability: 200pcs per week
    Contact Now
    Detailed Product Description
    Place Of Origin: Japan, Japan Type: Pressure Transmitter
    Stability: 0.1% Stability Per 10 Years Brand Name: Yokogawa, Yokogawa
    Output: 4 To 20 MA Weight: 3.7kg
    Model Number: EJX930A Quality: 100% Original New
    Lead Time: 8-10 Weeks Cover Flange: 316 SST
    Protocol: Hart FF Brain Profibus PA Mounting: 2-inch Pipe Mounting

    Yokogawa EJX930A Multi-Variable Pressure Transmitter

     

    Yokogawa EJX930A Multi-Variable Pressure TransmitterThe EJX range of transmitters is Yokogawa’s premium performance line of DPharp pressure transmitters. Released in 2004, it offers the most technologically advanced solution with class-leading performance and stability specifications. Additionally, the EJX family offers unique features such as standard IEC61508 certification, optional contact output, advanced diagnostics, multivariable mass flow measurement and ISA100 wireless capability.

     

     

    Descriptions

    1. The high performance EJX930A multivariable transmitter features a single-crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam mass fow.
    2. The EJX930A outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure, static pressure, process temperature, or dynamically calculated and fully compensated mass fow.
    3. Introducing the Yokogawa EJX930A multivariable transmitter, a remarkable innovation in multi-sensing technology that makes optimal use of the powerful characteristics of the single-crystal silicon resonant sensor.
    4. Experience EJXMVTool™(FSA120), PC-based software that is exclusively designed for use with the EJX930A. EJXMVTool™ enables users to configure mass flow and achieve accurate measurements with real-time full density compensation.
    5. FOUNDATION feldbus protocol type is also available.

    Specifications

      EJX930A Multivariable Transmitter
    M Capsule H Capsule
    Range Differential pressure -100 to 100 kPa
    (-400 to 400 inH2O)
    -500 to 500 kPa
    (-2000 to 2000 inH2O)
    Static
    pressure
    Absolute 0 to 32 MPa abs (0 to 4500 psia)
    Gauge -0.1 to 32 MPa (-14.5 to 4500 psig)
    External temperature -200 to 800 deg C (-328 to 1472 deg F)
    Span Differential pressure 1 to 100 kPa
    (4 to 400 inH2O)
    5 to 500 kPa
    (20 to 2000 inH2O)
    Static
    pressure
    Absolute/
    Gauge
    1 to 32 MPa (145 to 4500 psi)
    External temperature 10 to 1050 deg C (18 to 1890 deg F)
    Accuracy Mass flow ±1.0%
    Differential pressure ±0.04%
    Static pressure ±0.1%
    External temperature ±0.5 deg C (±0.9 deg F)
    Flow
    calculation
    reference
    Primary
    device
    Orifice Orifice Corner Taps [ISO5167-1 1991]
    Orifice Corner Taps [ISO5167-2 2003]
    Orifice Corner Taps [ASME MFC-3M 1989]
    Orifice Frange Taps [ISO5167-1 1991]
    Orifice Frange Taps [ISO5167-2 2003]
    Orifice Frange Taps [ASME MFC-3M 1989]
    Orifice Frange Taps [AGA No.3 1992]
    Orifice D and D/2 Taps [ISO5167-1 1991]
    Orifice D and D/2 Taps [ISO5167-2 2003]
    Orifice D and D/2 Taps [ASME MFC-3M 1989]
    Nozzle ISA1932 nozzle [ISO5167-1 1991/ISO5167-3 2003]
    Long radius nozzle
    [ISO5167-1 1991/ISO5167-3 2003]
    ASME FLOW NOZZLES [ASME MFC-3M 1989]
    Venturi Venturi nozzle [ISO5167-1 1991/ISO5167-3 2003]
    Classical Venturi tube "as cast" convergent section
    [ISO5167-1 1991/ISO5167-4 2003]
    ASME Venturi Tubes With a rought Cast or
    Fabricated Convergent [ASME MFC-3M 1989]
    Crassical Venturi Tubes With a machined convergent section
    [ISO5167-1 1991/ISO5167-4 2003]
    ASME Venturi Tubes With a machined convergent
    section [ASME MFC-3M 1989]
    Classical Venturi tube with a rought-welded sheet-
    iron convergent section
    [ISO5167-1 1991/ISO5167-4 2003]
    Density
    compensation
    of fluid
    General fluid DIPPR (Physical property database)
    Natural gas AGA No. 8, ISO 12213
    Steam IAPWS-IF97 Water and Steam, 1997
    Manual mode Flow factors being input manually
    Degrees of protection IP67, NEMA 4X, and JIS C0920 immersion proof
    Certificates FM, CENELEC ATEX, IECEx
    Output [HART protocol type]
    Dual output of 4 to 20 mA with pulse signals
    [ FOUNDATION fieldbus type]
    FOUNDATION fieldbus,2-wire system with
    digital communication
    HART Protocol Revision* HART protocol revision can be selected from 5 or 7 when ordering. The protocol revision can be changed by user configuration.
    Supply voltage HART:10.5 to 42 V DC
    (10.5 to 30 V DC for Intrinsically safe type)
    Fieldbus:9 to 32 V DC
    Ambient temperature -40 to 85 deg C (-40 to 185 deg F)
    (general use type)
    -30 to 80 deg C (-22 to 176 deg F)
    (with integral indicator)
    Process temperature -40 to 120 deg C (-40 to 248 deg F)
    (general use type)
    Maximum working pressure 32 MPa (4500 psi)
    Mounting 2-inch pipe mounting
    Wetted parts
    material
    Capsule 316L SST (Diaphragm material is Hastelloy C-276)
    Cover flange 316 SST
    Housing Cast aluminum alloy
    Flow configuration tool EJXMVTool™ EJX-MV Configuration DTM (FSA120)

     

    Selection Table

    *Note: Large size font is recomended for viewing.
    Model Application Type Capsule Measurement Span Maximum Working Pressure
    kPa inH2O MPa psi

    EJX110A
    Differential
    Pressure
    Traditional-
    Mounting*1
    F
    M
    H
    V
    0.1 to 5
    0.5 to 100
    2.5 to 500
    0.07 to 14MPa
    0.4 to 20
    2 to 400
    10 to 2000
    10 to 2000 psi
    16
    25
    25
    25
    2300
    3600
    3600
    3600

    EJX115A
    Flow Integral
    Orifice
    F
    M
    H
    1 to 5
    2 to 100
    20 to 210
    4 to 20
    8 to 400
    80 to 830
    16
    16
    16
    2300
    2300
    2300

    EJX118A
    Differential
    Pressure
    & Liquid
    Level
    with
    Remote
    Seals
    Extended
    Flush
    Combination
    M
    H
    2 to 100
    10 to 500
    8 to 400
    40 to 2000
    Based on Flange Rating

    EJX120A
    Draft
    Range
    Traditional-
    Mounting*1
    E 0.025 to 1 0.1 to 4 50 kPa 7.25

    EJX130A
    Differential
    Pressure
    & Liquid
    Level
    Traditional-
    Mounting*1
    M
    H
    1 to 100
    5 to 500
    4 to 400
    20 to 2000
    32
    32
    4500
    4500

    EJX210A
    Liquid
    Level,
    (Closed
    or Open
    Tank)
    Flush
    Extended
    M
    H
    1 to 100
    5 to 500
    4 to 400
    20 to 2000
    Based on Flange Rating

    EJX310A
    Absolute
    (Vacuum)
    Pressure*2
    Traditional-
    Mounting*1
    L
    M
    A
    B
    0.5 to 10
    1.3 to 130
    0.0175 to 3.5 MPa
    0.08 to 16 MPa
    0.15 to 2.95 inHg
    0.39 to 38 inHg
    2.5 to 500 psi
    12 to 2300 psi
    10 kPa
    130 kPa
    3.5
    16
    2.95 inHg
    38 inHg
    500
    2300

    EJX430A
    Gauge
    Pressure
    Traditional-
    Mounting*1
    H
    A
    B
    2.5 to 500
    0.0175 to 3.5 MPa
    0.08 to 16 MPa
    10 to 2000
    2.5 to 500 psi
    12 to 2300 psi
    500 kPa
    3.5
    16
    2000 inH2O
    500
    2300

    EJX438A
    Gauge
    Pressure
    with Remote
    Seal
    Flush A
    B
    0.035 to 3.5 MPa
    0.16 to 16 MPa
    5 to 500 psi
    23 to 2300 psi
    Based on Flange Rating
    Extended A
    B
    0.06 to 3 MPa
    0.46 to 7 MPa
    8.6 to 430 psi
    66 to 1000 psi

    EJX440A
    High
    Gauge
    Traditional-
    Mounting*1
    C
    D
    0.25 to 32 MPa
    0.25 to 50 MPa
    36 to 4500 psi
    36 to 7200 psi
    32
    50
    4500
    7200

    EJX510A
    EJX530A
    Absolute
    & Gauge
    Pressure*2
    Direct-
    Mounting
    A
    B
    C
    D
    8 to 200
    0.04 to 2 MPa
    0.2 to 10 MPa
    1 to 50 MPa
    1.16 to 29 psi
    5.8 to 290 psi
    29 to 1450 psi
    145 to 7200 psi
    200 kPa
    2
    10
    50
    29
    290
    1450
    7200

    EJX610A
    EJX630A
    A
    B
    C
    D
    2 to 200
    0.01 to 2 MPa
    0.05 to 10 MPa
    0.35 to 70 MPa
    0.3 to 29 psi
    1.5 to 290 psi
    7.3 to 1450 psi
    50.8 to 10150 psi
    200 kPa
    2
    10
    70
    29
    290
    1450
    10150

    EJX910A
    Multi-
    Variable
    Pressure
    Transmitter
    Traditional-
    Mounting*1
    L
    M
    H
    0.1 to 10
    0.5 to 100
    2.5 to 500
    0.4 to 40
    2 to 400
    10 to 2000
    16
    25
    25
    2300
    3600
    3600

    EJX930A
    M
    H
    1 to 100
    5 to 500
    4 to 400
    20 to 2000
    32
    32
    4500
    4500
    *1: Traditional-Mounting is 1/4NPT or Rc1/4 process connection (1/2NPT or Rc1/2 with process adapter).
    *2: Measurement values in Absolute for Absolute Pressure Transmitter.

     

     

    Origional Yokogawa EJX-A series differential pressure transmitter EJX930A

    Why do you choose us?
    1. 100% original package product, 100% quality assurance.
    If you find a fake product. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
    2. Varied payment methods.
    We adopt Paypal, T/T, Alibaba Trade Assurance order, and other methods. If you can not trust us , you can choose to pay it the other way! 100% make your money safe!
     
    We mainly supply Yokogawa flow meters, Emerson 475 field communicator, Emerson AMS Trex Device communicator, Siemens pressure transmitter, Honeywell transmitter, and the Honeywell BW gas analytics.
     
    Wuhan Xieyuan Automation Equipment Co., Ltd
    Telephone:86-027-85583233
    Mobile Phone:86-18671080257
    Fax:86-027-85309780
    Contact : victor@whxyauto.com
    Skype:victordu963@gmail.com
    Whatsapp & Viber are available
    Address:6-C9,Caishen Commercial Plaza,Hankou Railway Station

    Origional Yokogawa EJX-A series differential pressure transmitter EJX930A

     

    Contact Details
    WUHAN XIEYUAN AUTOMATION EQUIPMENT CO.,LTD

    Contact Person: Mr. Victor

    Tel: 86-027-85883233

    Fax: 86-027-85309780

    Send your inquiry directly to us (0 / 3000)